Dual MPPT design supports up to 12 kW or 16 kW solar input with up to 600 V PV voltage.

Hybrid Inverters
G6000 / AG8000 Hybrid Inverters
Compare AMPEXE G6000 and AG8000 hybrid inverters with dual MPPT input, 48 V battery support, IP66 protection, and grid-backup operation for OEM and project supply.
Dual MPPT design supports up to 12 kW or 16 kW solar input with up to 600 V PV voltage.
Works with lead-acid and lithium batteries, with charge and discharge current up to 160 A.
Provides 6 kW or 8 kW hybrid output, peak backup power up to 16 kVA, and switching under 4 ms.
Request a quotation
Ask about MOQ, lead time, market versions, packaging, and available OEM options.
Review the model-specific details.
Compare the listed electrical, mechanical, protection, and integration information before selecting a configuration.
Hybrid inverters for grid-tied solar, battery backup, and monitored residential energy systems.
Works with lead-acid and lithium batteries, with charge and discharge current up to 160 A.
Provides 6 kW or 8 kW hybrid output, peak backup power up to 16 kVA, and switching under 4 ms.
IP66 protection, listed protection functions, Wi-Fi and LAN monitoring, and wall-mounted installation.
Model specifications
Technical specifications
Compare electrical, mechanical, operating, and model-specific parameters for the available configurations.
Match the model and market version to the required system configuration before ordering.
Swipe horizontally to compare every model column.
| Model | G6000 | AG8000 |
|---|---|---|
| Battery Input Data | ||
| Type | Lead-acid / Li-Ion | Lead-acid / Li-Ion |
| Battery Voltage Range (V) | 40-60 | 40-60 |
| Nominal Battery Voltage (V) | 48 | 48 |
| Max. Charge/Discharge Current (A) | 120 | 160 |
| Max. Charge/Discharge Power (W) | 6000 / 6600 | 8000 / 8800 |
| PV String Input Data | ||
| Max. PV Input Power (W) | 12000 | 16000 |
| Max. PV Input Voltage (V) | 600 | 600 |
| Working Voltage Range (V) | 50-550 | 50-550 |
| First Feed-in Voltage (V) | 60 | 60 |
| Nominal PV Input Voltage (V) | 380 | 380 |
| Max. Input Current (A) | 20 / 20 | 20 / 40 |
| Max. Short Current (A) | 27 / 27 | 27 / 54 |
| No. of MPP Trackers | 2 | 2 |
| Strings per MPP Tracker | 2 | 1+2 |
| AC Output Data (On-grid Port) | ||
| Nominal Power Output to Grid (VA) | 6000 | 8000 |
| Max. Power Output to Grid (VA)* | 6600 | 8800 |
| Max. Power from Grid (VA) | 12000 | 12000 |
| Nominal Output Voltage (V) | 220/230/240, L/N/PE | 220/230/240, L/N/PE |
| Nominal Output Frequency (Hz) | 50/60 | 50/60 |
| Nominal AC Current to Grid (A) | 27.3 / 26.1 / 25 | 36.4 / 34.8 / 33.4 |
| Max. AC Current to Grid (A) | 30 | 40 |
| Max. AC Current from Grid (A) | 40 | 50 |
| Power Factor | Adjustable from 0.8 leading to 0.8 lagging | Adjustable from 0.8 leading to 0.8 lagging |
| THDi (Nominal Power) | <3% | <3% |
| AC Output Data (Back-up Port) | ||
| Max. Continuous Output Power (VA) | 6600 | 8800 |
| Peak Output Power (VA) | 12000 @10s | 16000 @10s |
| Max. Output Current (A) | 30 | 40 |
| Nominal Output Voltage (Vac) | 220/230/240, L/N/PE | 220/230/240, L/N/PE |
| Nominal Output Frequency (Hz) | 50/60 | 50/60 |
| Output THDv (@Linear Load) | <3% | <3% |
| Switch Time | <4ms | <4ms |
| AC Input Data (Generator Port / Load Control Port) | ||
| Nominal Input Apparent Power (VA) | 6000 | 8000 |
| Max. Input Apparent Power (VA) | 12000 | 12000 |
| Max. AC Input Current (A) | 40 | 50 |
| Nominal Input Voltage (V) | 220/230/240, L/N/PE | 220/230/240, L/N/PE |
| Nominal AC Generator Frequency (Hz) | 50/60 | 50/60 |
| Efficiency | ||
| Max. Efficiency | 97.6% | 97.6% |
| Euro Efficiency | 96.5% | 96.5% |
| General Data | ||
| Operating Temperature Range (°C) | -30-60 | -30-60 |
| Relative Humidity (%) | 0-100% | 0-100% |
| Operating Altitude (m) | <3000 | <3000 |
| Cooling | Intelligent Air Cooling | Intelligent Air Cooling |
| Noise (dB) | <30 | <40 |
| Weight (kg) | 17 | 40 |
| Size (W/H/D) (mm) | 501*586*193 | 501*586*193 |
| Installation | Wall-Mounted | Wall-Mounted |
| Protection Degree | IP66 | IP66 |
| Protection | ||
| Anti-island Protection | Integrated | Integrated |
| PV Insulation Resistance Detection | Integrated | Integrated |
| PV Reverse Protection | Integrated | Integrated |
| Residual Current Monitoring Unit | Integrated | Integrated |
| AC Over Current/Voltage Protection | Integrated | Integrated |
| DC Switch (PV) | Integrated | Integrated |
| Surge Protection | DC Type III / AC Type III | DC Type III / AC Type III |
| Communication Interface | ||
| Battery BMS | CAN | CAN |
| EMS (Modbus) | RS485 | RS485 |
| Meter (Outside) | RS485 | RS485 |
| RCR/DRED | YES (DI) | YES (DI) |
| Remote Shut Down | YES (DI) | YES (DI) |
| Dry contact | YES (DO) | YES (DO) |
| Cloud | Wi-Fi, LAN | Wi-Fi, LAN |
| Display/User Interface | LED / LCD / APP | LED / LCD / APP |
| Certifications & Standards | ||
| Grid Regulation | IEC61727, IEC62116, EN50549-1, NRS097, G98, G99 | IEC61727, IEC62116, EN50549-1, NRS097, G98, G99 |
| Safety Regulation | IEC/EN62109-1&2 | IEC/EN62109-1&2 |
| EMC | IEC/EN61000-6-1/2/3/4 | IEC/EN61000-6-1/2/3/4 |
Select with the complete system in mind.
Start with the application, then confirm electrical fit, environment and order requirements against the selected model.
Define the power profile
List continuous loads, startup demand and backup priorities before selecting an output model.
Check the PV window
Match the planned array voltage and power to the stated PV input and MPPT limits for the selected model.
Verify storage compatibility
Confirm battery voltage, chemistry, charge current and communication requirements against the quoted configuration.
Plan the installation
Review mounting, enclosure protection, monitoring, parallel operation and local electrical requirements where applicable.
Confirm the full system, not one feature
The listed transfer, surge, monitoring and protection features apply within quoted operating limits. Confirm PV, battery, grid and installation compatibility, plus local requirements, before approval.
Ask which current datasheet, user manual, packing list and market-specific order documents apply to the exact quoted configuration.

Designed for the modern home energy room
A wall-mounted format, IP66 protection, and remote monitoring options make this hybrid platform a considered choice for organized solar and storage projects.
Residential solar and storage
Dual MPPT input and compatibility with lead-acid or lithium batteries support integrated home energy system planning.
Fast home backup
The 6 kW and 8 kW output options combine peak backup capability with switching under 4 ms.
Higher-input hybrid projects
The available solar input capacity and high PV voltage range suit projects that need more room for array design.
Discuss the required market configuration.
Use the inquiry to discuss available electrical configurations, branding, packaging, documentation, and project requirements.
Configuration options
Ask which branding, interface, enclosure, and packaging options are available.
Commercial planning
Confirm quantity, lead time, destination market, and documentation.